Cleanroom Wipes
Polyester Cleanroom Wipes 1009B Mesh 115 g/m²
| Material | Polyester yarn |
|---|---|
| Construction | Knitted mesh |
| Basis weight | 115 g/m² |
| Thickness | 0.48 mm |
| Edge options | Laser sealed; Ultrasonic sealed; Hot cut; Wide ultrasonic seal |
| Washing designations | Class 1000 |
| Size options | 4 in; 6 in; 9 in; 12 in; Custom sizes |
| Listed water absorption | ≥230 — unit/method to confirm |
| Packaging | Vacuum inner pack with two-layer outer packaging |
Washing designations describe processing options, not sterility. Absorption figures require a confirmed test unit and method before comparison.
1009B uses a relatively light polyester mesh with an open, absorbent surface. It is intended for routine particle pickup and wet wiping around PCB exposure operations and glass-related production.
For particles that must leave with the wipe
Dust remaining on exposure equipment or a glass surface can transfer back into the process. 1009B combines an open mesh with a soft fabric face so a controlled wiping pass can collect loose contamination rather than repeatedly pushing it across the same area.
- Remove loose abrasive debris without rubbing it into the surface.
- Apply the approved liquid in a controlled amount; a dripping wipe can move contamination into joints.
- Wipe in one direction, exposing a fresh folded face for the next pass.
Acceptance on the actual surface
Evaluate particle pickup, residual liquid and visible streaking on the actual glass or equipment finish. Cleanroom washing terminology describes processing choices and does not replace a surface-cleanliness acceptance test.
Sheet sizes and packing
| Sheet size | Sheets / bag | Bags / carton |
|---|---|---|
| 4 × 4 in | 600 | 20 |
| 6 × 6 in | 150 | 20 |
| 9 × 9 in | 150 | 10 |
Confirm the selected size, edge, washing condition and packing together when ordering.
Fabric and product details


Documentation to request
RoHS; Halogens; Silicone oil; Ionic contamination; Liquid particle count (LPC); Composition; Cleanliness.
Confirm report availability, test method and applicability to the selected finished product before ordering.
Application areas
Laboratory research; Semiconductor processes; LCD panels; Optical products; Precision electronics; Pharmaceutical production; Biomedical work areas.
Choose the contact surface, cleaner and acceptance criteria for the actual task. An application listing does not establish sterile or medical-device status.
Contact shengtongjh to discuss the sheet size, finishing and packing required for your application.