Cleanroom Wipes
Microfiber Cleanroom Wipes 8009J 195 g/m²
| Material | Polyester and nylon |
|---|---|
| Construction | Knitted straight texture |
| Basis weight | 195 g/m² |
| Thickness | 0.34 mm |
| Edge options | Laser sealed; Ultrasonic sealed; Hot cut; Wide ultrasonic seal |
| Washing designations | Class 100; Class 1000 |
| Size options | 4 in; 6 in; 9 in; 12 in; Custom sizes |
| Listed water absorption | ≥300 — unit/method to confirm |
| Packaging | Vacuum inner pack with two-layer outer packaging |
Washing designations describe processing options, not sterility. Absorption figures require a confirmed test unit and method before comparison.
8009J is a polyester-nylon microfiber wipe for controlled removal of fingerprint and oil films. Its thin straight-knit construction gives an alternative to bulkier microfiber grades.
A thin cloth with a substantial fabric weight
Basis weight and thickness describe different properties. 8009J combines a substantial listed fabric weight with a relatively thin profile, making it worth evaluating where the operator needs a close fold without excessive bulk.
Check how the folded cloth follows the surface and releases liquid under light pressure. A heavier weight does not automatically mean faster pickup or lower residue.
From fingerprint to clean finish
Use an approved cleaner to release the film, collect it on a fresh working face and inspect after drying. If a haze remains, change the cloth face and review the liquid load before repeating the same pass.
Keep cloths used on frames or equipment housings separate from those used on the final glass surface. The surrounding hardware can carry abrasive particles even when the glass appears only lightly marked.
Confirm the sheet count for the selected format when ordering; the available source packing descriptions differ for the medium-size sheet.
Sheet sizes and packing
| Sheet size | Sheets / bag | Bags / carton |
|---|---|---|
| 4 × 4 in | 400 | 20 |
| 6 × 6 in | 100 | 20 |
| 9 × 9 in | 100 | 10 |
Packing shown follows the detailed specification. A separate listing gives different sheet counts; confirm the selected pack before ordering.
Fabric and product details


Documentation to request
RoHS; Halogens; Liquid particle count (LPC); Cleanliness.
Confirm report availability, test method and applicability to the selected finished product before ordering.
Application areas
Laboratory research; Semiconductor processes; LCD panels; Optical products; Precision electronics; Pharmaceutical production; Biomedical work areas.
Choose the contact surface, cleaner and acceptance criteria for the actual task. An application listing does not establish sterile or medical-device status.
Contact shengtongjh to discuss the sheet size, finishing and packing required for your application.